Intertek can assist with all facets of acoustical testing, helping you meet third-party acoustical and airflow performance requirements defined by specifiers, buyers, and regulatory authorities
Intertek can assist with all facets of acoustical testing, helping you meet third-party acoustical and airflow performance requirements defined by specifiers, buyers, and regulatory authorities
Turnaround times for many of our tests are less than two week from receipt of sample to issuing of test report.
We offer a wide range of acoustical, airflow, and leakage testing services on products like air conditioners, dishwashers, windows and doors. Our acoustical and airflow testing laboratory is one of the most extensive and diversified facilities of its kind.
- Association Testing: We test according to Air-Conditioning, Heating, and Refrigeration Institute (AHRI) and Air Movement and Control Association (AMCA) program requirements.
- Leakage Testing: We perform leakage testing on several different product types including recessed lighting, air handler cases, PTACs, and others.
- Residential Range Hood Program Testing: We offer comprehensive testing to meet requirements for California Energy Commission title 20 as well as sound, airflow and capture efficiency to meet program requirements.
- Product Development Assistance: We can conduct testing characterizing the sound and airflow performance of alternate components and designs.
- Field Tests and Verifications: We perform many types of field tests and verifications, including: FIIC, ASTC, NIC, NNIC, Sound Power, Sound Pressure, and Sound Intensity.
- Enclosures and Office Spaces: We offer the latest acoustic testing for isolated booths becoming more common in office and public spaces. Testing in accordance with ASTM E596 and ISO 23351-1 “Acoustics — Measurement of speech level reduction of furniture ensembles and enclosures”
- Life Safety Acoustics Testing: We offer a comprehensive set of acoustics and electroacoustics testing related to fire alarm systems and emergency phones.
- Medical Devices and Handheld Tools: Sound power level testing and hand transmitted vibration testing for many IEC and ISO standard
Our floor ceiling assemblies include 6” concrete, 6” concrete with ceiling plenum, and a 100 sq. ft. floor opening for custom floor/ceiling systems to ASTM and ISO. The 6” concrete is also used for Delta IIC measurements.
Examples of products we test include:
Building Materials and Assemblies
Partitions (i.e., office panels), walls, doors, windows and floor/ceiling assemblies, carpeting, wall coverings, acoustical panels and ceiling tiles, duct liner materials and prefabricated silencers (standard size 2’x2’, round, straight, or elbow), recessed lights

Mechanical Equipment and Accessories
Outdoor unitary air conditioning equipment, ducted and non-ducted indoor air conditioning equipment, grilles, registers and diffusers, air control and distribution devices, fans, blowers and other air moving devices, machines, mechanical and electrical equipment and sub-assemblies; and hand-held power tools.
Household Appliances
Room air conditioners, room air cleaners, vacuum cleaners, clothes washers, dishwashers, blenders, mixers, can openers and other small and large appliances.
Our facilities include multiple reverberation rooms:
- Main Room: Sound absorption, Sound Power, and Receiving room for sound transmission testing; room size 470 m3/16400 ft3
- Second Room: Source room for horizontal sound transmission testing, receiving room for vertical sound transmission testing and impact insulation class; room size 283m3/10000 ft3
- Third Room: Source room for vertical sound transmission testing and source room for impact insulation class testing; 65 m3/2300 ft3
- Fourth Room: Source room for impact insulation class over 6” concrete and 6” concrete with a ceiling plenum
- Hemi or Semi-Anechoic Room: Test room for sound pressure, sound power, articulation class; room size 115 m3 / 4000 ft3
- Air Diffusion Test Room: Facility for testing Grilles, registers, diffusers and related equipment
- Low Noise, High Flow Air Supply: 11,000 Cubic Feet per Minute (CFM) quiet air supply for testing ducts, silencers and terminal air units with measuring stations from a few CFM to the full 11,000
Acoustical Testing Resources
Air Cleaner Sound Testing | Fact Sheet
Explore how Intertek’s Air Cleaner Sound Testing supports innovation in a growing market for quiet, efficient air cleaning solutions and see how our experts can evaluate your products to AHAM AC-2 and ISO 3741 requirements.
HVAC Sound Power Testing | Fact Sheet
Discover how Intertek's HVAC Sound Power Testing services help manufacturers demonstrate compliance with key acoustical requirements, including AHRI 260, AHRI 270, AHRI 300, AHRI 350, and AHRI 880.
Acoustical Testing – Sound Power Level | Fact Sheet
Learn how Intertek's Sound Power Level Testing services provide manufacturers with precise data to support compliance with ISO 3741, ISO 3744, ISO 9614-2, and other key standards.
Air Leakage Testing | Fact Sheet
See how Intertek's Air Leakage Testing services can help manufacturers improve energy efficiency, reduce system losses, and ensure compliance with key industry standards.